[. . . ] Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 2. Serial Interface Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 2. 1. Transfer Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 2. 2. Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 3. [. . . ] Acceptable Unacceptable [ACK] [CR] ""[CR] 6. 12. VOLUME ­ Command Command Detail Response "C0A" [CR] Volume Down This command operates the same as VOLUME - button of remote control. Acceptable Unacceptable [ACK] [CR] ""[CR] 6. 13. AUDIO MUTE ON Command Command Detail "C0B" [CR] Sound Mute ON This command works the same as "MUTE" button of the remote control for Mute ON, but does not work for Mute OFF. Acceptable Unacceptable [ACK] [CR] ""[CR] Response 6. 14. AUDIO MUTE OFF Command Command Detail "C0C" [CR] Sound Mute OFF. This command works the same as "MUTE" button of the remote control for Mute OFF, but does not work for Mute ON. Acceptable Unacceptable [ACK] [CR] ""[CR] Response 6. 15. VIDEO MUTE ON Command Command Detail "C0D"[CR] Video Mute ON. This command works the same as "NO SHOW" button of the remote control for No Show ON, but does not work for No Show OFF. Acceptable Unacceptable [ACK] [CR] ""[CR] Response 11/23 PLC-XE50 Basic Serial Command Specifications 6. 16. VIDEO MUTE OFF Command Command Detail "C0E" [CR] Video Mute OFF. This command works the same as "NO SHOW" button of remote control for No Show OFF, but does not work for No Show ON. Acceptable Unacceptable [ACK] [CR] ""[CR] Response 6. 17. Screen Normal size Command Command Detail Response "C0F" [CR] Set screen size to Regular(4:3). Acceptable Unacceptable [ACK] [CR] ""[CR] 6. 18. Screen Wide size Command Command Detail Response "C10" [CR] Set screen size to Wide (16:9). Acceptable Unacceptable [ACK] [CR] ""[CR] 6. 19. Image Standard Command Command Detail Response "C11" [CR] Set Image to Standard mode. Acceptable Unacceptable [ACK] [CR] ""[CR] 6. 20. Image Real Command Command Detail Response "C12" [CR] Set Image to Real mode. Image Cinema Command Command Detail Response "C13" [CR] Set Image to Cinema mode. Acceptable Unacceptable [ACK] [CR] ""[CR] 12/23 PLC-XE50 Basic Serial Command Specifications 6. 22. Image 1 Command Command Detail Response "C14" [CR] Set image to Image 1 mode. Acceptable Unacceptable [ACK] [CR] ""[CR] 6. 23. Image 2 Command Command Detail Response "C15" [CR] Set image to Image 2 mode. Acceptable Unacceptable [ACK] [CR] ""[CR] 6. 24. Image 3 Command Command Detail Response "C16" [CR] Set image to Image 3 mode. Acceptable Unacceptable [ACK] [CR] ""[CR] 6. 25. Image 4 Command Command Detail Response "C17" [CR] Set image to Image 4 mode. Acceptable Unacceptable [ACK] [CR] ""[CR] 6. 26. Image Blackboard(Green) Command Command Detail Response "C18" [CR] Set image to Blackboard (Green) mode. Image Dynamic Command Command Detail Response "C19" [CR] Set image to Dynamic mode. [. . . ] "88"[CR] Status : Coming back after temperature anomaly When the status moves to Standby after Cooling Down due to temperature anomaly, it returns "88" [CR]. This shows that the status turns to Standby because of abnormal temperature. When Power On is executed, the information of temperature anomaly is canceled and normal operation is executed. 21/23 PLC-XE50 Basic Serial Command Specifications 7. 3. 8. "24"[CR] Status : Processing Power Save / Cooling Down Power management function in the Setting menu works and the status goes to Power Save / Cooling Down. [. . . ]